Pellet Stove Vent Pipes. Christina from Stoddard, NH asked: January 3, 2. What is the procedure for installing pellet vent piping? Answers. Because pellet stoves operate using a combustion fan system, their venting systems share many similarities to direct vent gas appliances. Like direct vent fireplaces, pellet venting can be routed horizontally to an outside wall and terminated or it can be routed vertically for a short run before terminating. It is recommended to employ a short vertical run externally before terminating, as this will prevent the appliance from leaking smoke into the room if a power outage is experienced. Having the short vertical run allows negative pressure to pull residual smoke from the appliance after shutdown. For cleaning purposes, it is recommended to keep the vent run free of any unneccessary bends or turns. Flame FP-45 Pellet Fuel Burning Stove Pellet fuel burning stoves are a wonderful, efficient alternative to traditional wood burning stoves, and this Flame FP-45. Choosing the best pellet stoves for your home doesn't need to be a difficult task thanks to our useful and insightful buying guide. Use for a single-wall connector pipe. Requires 18" clearance to combustibles. DuraBlack is to be used with single-wall interior stovepipe for connecting wood stoves. This will allow you to complete the cleaning procedure more effectively and prevent the build up of ash in the vent system. Of course, each pellet stove manufacturer will differ and it is important to employ an installation that will meet their standards. Local codes should also be consulted. With this information in hand, our NFI trained technicians will be happy to put a materials quote together for you, via our vent quote form. Tyler M. - Fireplace Specialist on January 3, 2. Mark from Bel Air, MD asked: December 2. · · One of the best ways to be safe and save yourself a BIG headache is to use the right kind of Pipe for your Chimney and Fireplace Installation. I have been. I have a new pellet stove and I want to run the piping through the existing wood- burning fireplace chimney flue. Is there a special plate/adapter that I put in the flue to allow the pipe to pass through but keep the rest of the air space closed? Answers. This is typically done by cutting sheet metal to fill the void between the damper opening and pellet vent. Will M. on December 2. John from Golden, CO asked: November 2. I have read, living at 7. I need a 4" horizontal kit. I like the Selkirk product but do not see 4" pipe kit. Do you carry something like this? Answers. Rick from Garden City, MO asked: December 1. I am looking to Install a Breckwell P2. FSL Pellet stove. Can it be directly vented into my existing masonry chimney or do I have to put in a chimney liner? Will it vent correctly if it is direct vented? Answers. This unit is able to be vented into a masonry chimney, but a liner must be installed in order for the unit to vent directly. The relatively large cross section of a masonry chimney flue will cause flue gases to stagnate otherwise, which can lead to spillage of combustion gases back into the room and generally poor operation. Fireplace. Store on December 1. Danny from Salisbury, MD asked: December 4, 2. I have a Paragon by US Stoves model 5. Q. All my vent pipe is the 3 inch Dura. Vent twist lock pipe. I am looking for an adapter to go from the stove to the 3" pipe. The pipe coming out of the stove is 3 inch and the 3 in pipe will not fit over it to connect to the stove. Do you carry an appliance adapter for this stove? Answers. Travis from Fort Frances, Ontario Canada asked: October 2. What type of chimney flex liner can I use for the exhaust on a pellet stove?It will be going in an existing masonry chimney.I have a Whitfield Advantage II WP2 Insert pellet stove and 2.Masonry chimney. 1 Answers.According to the manual for your stove, the cutoff to switch from 3 inch to 4 inch occurs at approximately 2.As such, a 4 inch stainless steel flex liner should be used. here. Collin C. - NFI Master Hearth Professional on October 2. Mike Quinton from Keene, NH asked: November 2. Can a Harmon XXV pellet stove be vented directly into a 1. Is there sufficient draft? Answers. Per the published information for this stove, it is indeed possible to vent this model into a clay lined masonry chimney, as long as the clay tiles are proven to be in good condition. The combustion fan will provide adequate positive pressure for the unit to draft in this way. Lining the chimney with a 4 inch stainless steel liner is recommended if the condition of the chimney is questionable in any way. Collin C. - NFI Master Hearth Professional on November 2. How far from a window must the pellet vent pipe be from windows? Answers. Per national code, the termination for a conventional pellet vent appliance cannot be closer than 4 feet to a door or window. Please be sure to check with your local code office, as they may have a different requirement. Local jurisdiction has final authority. Please let me know if I can assist you further. more.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
October 2017
Categories |